Philips Respironics DreamStation Heated Humidifier
Philips Respironics DreamStation Heated Humidifier
This product requires a prescription.
Learn moreShips same day if ordered before 4 PM CST
Free shipping on orders over $99
100% price match guarantee
FSA/HSA eligible
DreamStation Heated Humidifier
Prescription Required
Federal law requires us to have a valid prescription on file before we ship your CPAP mask, machine, humidifier, oral appliance, or EPAP device. Once we receive your script, we will be able to process your order. You will have an opportunity to submit your prescription during the checkout process.This documentation can be submitted in the following ways:
- Email us a photo of your prescription
- Fax us a copy of your script
- Let us contact your doctor for you
Don’t have your prescription? No problem! We’re here to simplify your sleep apnea journey. cpap.com is proud to offer prescription renewal services or at-home sleep apnea testing.
Water Chamber for AirSense 10, AirStart 10, and AirCurve 10 HumidAir Heated Humidifier
Standard CPAP Hose (CPAP Tubing) - 6 Foot Long 19mm Diameter with 22mm Rubber Ends
Filters for Airsense Machines - Series 10
HumidX for AirMini Travel CPAP Machine
Nasal Pillows for AirFit P10 Nasal Pillow Mask
Full Face Cushion for AirTouch F20 Mask
AirSense 11 Disposable Filters
SlimLine Tubing for AirSense 11, AirSense/AirCurve 10, & S9 CPAP/BiPAP Machines
Cushion and Clip for Mirage Quattro Full Face Mask
ClimateLineMAX Oxy Air Tubing with Supplemental Oxygen Port For S9 Machines
Headgear for AirFit F20 and AirFit F20 For Her Full Face Mask
Heated Tube for DreamStation CPAP Machines
AirMini Mask Setup Pack
Cushion for AirFit F20 and AirFit F20 For Her Full Face Mask
Generic Outlet Bacteria Filter
Filters for DreamStation Machines
AirMini Fine Filters
Nasal Pillows for Swift FX CPAP Mask
Headgear for AirFit P10 Nasal Pillow CPAP Mask
Standard Water Chamber for AirSense 11 Humidair Heated Humidifier
Cushion for AirFit N20 & AirFit N20 for Her Nasal CPAP Masks
AirMini Premium Carry Bag
Water Chamber for DreamStation Heated Humidifier
Frame for DreamWear CPAP Masks
CPAP.com Medical Identification Luggage Tag for CPAP Equipment
Cushion for AirFit N30i Nasal CPAP Mask
Machine Travel Case for AirMini Travel CPAP Machine
Zephair AirMini Universal Adapter - Use Any Mask!
Memory Foam Nasal Replacement Cushion for AirTouch N20, AirFit N20, and AirFit N20 for Her
Heat Moisture Exchange Unit for CPAP Machines
Filters for DreamStation 2
Headgear for DreamWear Nasal CPAP Mask
ResMed AirMini Mask Connector
Power Supply for AirSense 11 CPAP Machines
Headgear for AirFit N20 & AirFit N20 for Her Nasal CPAP Masks
Nasal Cushion for DreamWear CPAP Mask
Short Tube Assembly for Swift FX Nasal Pillow (elbow, short tube, and swivel)
Washer for SleepWeaver Elan Nasal CPAP Mask
Healthy Hose Pro Antimicrobial CPAP Tubing
Water Chamber for PR System One Heated Humidifiers - Universal Kit
Nasal Pillows for AirFit P30i Nasal Pillow Mask
Sunset 6 Foot CPAP Tubing
Cushion for AirFit F30 Full Face Mask
DC Converter 24V 90W For AirStart 10, AirSense 10, and AirCurve 10 Machines
Dual-Wall Spring Air Cushion for Mirage FX Nasal CPAP Mask
ResMed AirFit F30i Cushion Replacement
Cushion for AirFit F10 and Quattro Air Full Face Mask
This product requires a prescription. Learn More
-  
-  
Details
MoreOptimize your comfort while you sleep with the DreamStation Heated Humidifier , designed to add heated humidification to your therapy air. Built for compatibility with the DreamStation CPAP machine line from Philips Respironics, the DreamStation Heated Humidifier offers a variety of convenience and comfort features!
Find all compatible parts listed here on the DreamStation Parts page.
DreamStation Heated Humidifier Features and Benefits:
- Adaptive Humidification to Automatically Adjust to Your Needs
- Prevent Leaks With Dry Box Technology
- Compatible With DreamStation Series Machines
- Easy to Clean and Fill Chamber Design
- Holds Up to 325 mL of Water-Which Can Last up to 8 Hours
- Compatible With: standard 22mm hose, slim 15mm hose, and DreamStation slim 15mm heated hose
Adaptive Humidification to Automatically Adjust to Your Needs
The DreamStation Humidifier offers two operating modes: a standard fixed heating mode and an adaptive mode that automatically adjusts the heat and moisture levels. Adaptive mode is designed to provide the optimal moisture level while minimizing condensation build-up.
Prevent Leaks With Dry Box Technology
When used with a heated tube, Dry Box Technology helps reduce the risk of water damage in the event water escapes the water chamber. The air outlet port is outfitted with a one-way valve that helps prevent water displacement, as well.
General Tips Section
Heated Humidifier Specifications
- Maximum Temperature - Heater Plate: 149 degrees F (65 degrees C)
- Maximum Pressure Drop with Humidifier: 0.6 cm H2O at 60 LPM flow
- Atmospheric Pressure: 0 - 7500 ft (0 - 2286 m) (101 to 77 kPA)
- Maximum Recommended Pressure: 25 cm H2O
- Mode of Operation: Continuous
- Sound Pressure Level (Machine and Humidifier): 27.9 dB(A) with an uncertainty of 2 dB(A)
- Sound Power Level (Machine and Humidifier): 35.9 dB(A) with an uncertainty of 2 dB(A)
- Languages: English or Spanish
Optional Heated Tube Specifications
We recommend using the optional heated tubing with your CPAP therapy, as it ensures a consistent humidity level and constant heat for your CPAP therapy pressure as it travels from the optional humidifier of your DreamStation device, through the heated hose, and to your CPAP mask. Optional heated tubing helps to prevent rainout, the buildup of condensation in the CPAP hose during sleep therapy.
- Maximum Recommended Pressure: 25 cm H2O
- Heated Tubing Temperature Range: 60 degrees F to 86 degrees F (16 degrees C to 30 degrees C)
- Heated Tubing Temperature Cut-Off: Equal to or Greater than 106 degrees F (Equal to or Greater than 41 degrees C)
User Manual:
The user manual included with the DreamStation humidifier can be viewed and downloaded here: DreamStation Heated Humidifier .
Water Chamber Tips
- Do not fill the water chamber past the maximum fill line.
- Remove the water chamber from the humidifier before filling it with water.
- Fill the water chamber with room temperature, distilled water only.
- The water chamber is designed to be hand washed daily with mild soap and warm water.
- The chamber may be washed in a dishwasher once per week on the top shelf only.
- Disassemble the water chamber from the humidifier before traveling.
- Do not use the humidifier without the water chamber. If the tank is not being used, the humidifier must be set to 'OFF'.
- Please Note: If the humidifier was recently used, the heater plate below the water chamber will remain warm for 15 minutes. Wait for the heater plate to cool before removing the water chamber.
Tips for Accessing the Water Chamber
The water chamber is enclosed inside the humidifier. To access the water chamber, find the tab located on the top of the humidifier. Gently push the tab forward to release the humidifier wall. The panel will open completely, exposing the water chamber. Cautiously remove the water chamber with both hands, place it on a flat surface to fill it with water, and return the chamber to the humidifier. Please Note: Do not fill the water past the maximum fill line.
Before beginning therapy, ensure the humidifier lid is securely closed and re-attach the device to power.
Travel Tips
Do not move the humidifier when the chamber is filled with water. As a rule of thumb, always remove the tank from the humidifier and extract all of the water when preparing to travel. Let the humidifier chamber air dry completely after the water is emptied before returning the chamber to the humidifier. When all the equipment is dry, place the device in a carry-on bag to help protect the unit. Per the manufacturer, the carrying bag cannot guarantee the safety of the equipment when checked as luggage, so use the bag as a carry-on only.
Present the text on the bottom of the humidifier or purchase an OPTIONAL CPAP.com Medical Identification Luggage Tag for CPAP Equipment to clarify that the carry-on holds medical equipment.
When traveling to other countries, remember to switch to universal or compatible power cords and adaptors. Do not use the humidifier while aboard the flight.
Caring for the Humidifier Lid Seal
The seal found under the top of the humidifier lid is designed to fasten the lid to the humidifier when closed. On occasion, the seal may need to be cleaned or replaced to sustain the strong grip. Follow these steps when cleaning the seal:
- For simple, daily cleanings, use a damp cloth to wipe the circumference of the seal.
- For more complex cleanings, remove the seal cautiously and place it in warm water. Cleanse the seal with mild soap and continue to rinse with warm water. Wipe the seal to remove excess water and place it out of the sunlight to air dry completely.
If the seal is still in good condition, it may be re-installed on the humidifier lid. Line the hole of the seal with the interior form of the humidifier outlet port. To ensure the direction of the seal is correct, align the wire channel found in the center of the hole with the bottom of the air outlet. The seal will not feel secure until it has been pressed into the border of the humidifier lid. Press the center of the seal to solidify the grip around the outlet.
Assembly Tips
How to Connect and Disconnect the DreamStation Machine and Humidifier
- Connect the DreamStation Machine and Humidifier
Please Note: Empty the water chamber before moving the humidifier to protect the machine from potential water damage. The humidifier should never be placed directly onto carpet, fabric, or other flammable surfaces.
The air outlet port found on the back of the DreamStation devices will line up with the front of the humidifier which is indicated by the opening for the water chamber. Once the machine's air outlet is directly connected to the humidifier's air inlet port, the two devices may be joined by sliding them together until a clicking noise is heard.
- Disconnect the DreamStation Machine and Humidifier
Begin by removing the water tank from the humidifier. Next, make sure the unit is disconnected from the power source. Grasp the machine and humidifier with both hands. Position one hand on the machine, while placing the other hand on the humidifier release button found along the bottom rim of the humidifier. Gently pull the machine and humidifier apart while holding the release button.
How to Connect and Disconnect the Tube to the Humidifier
The DreamStation Humidifier is compatible with standard 22 mm hoses, slim 15 mm hoses, and the 'optional' heated 15 mm hose.
- Connect the Tube and the Humidifier
The heated tube has a connector located on the bottom cuff of the CPAP hose. When attaching the heated hose, align the connector with the air outlet port on top of the humidifier. The clicking sound that is made by the fasteners attaching to the air outlet port will signify the hose is properly attached.
To position a standard 22mm hose or a slim 15mm hose, slide the cuff of the CPAP hose over the air outlet port.
- Disconnect the Tube and the Humidifier
To disconnect the OPTIONAL heated hose, carefully press the clips at the connection point on the tube to disconnect the hose from the air outlet port.
When disconnecting a standard 22mm hose or a slim 15mm hose, use slight pressure to pull the cuff from the port.
Cleaning / Maintenance Tips
Cleaning Tips
Before cleaning the humidifier, be sure the device has been disconnected from power and from the DreamStation machine. Use a damp cloth and mild detergent to gently clean the surface of the humidifier. Do not submerge the unit underwater. The air outlet port on the top of the humidifier may be cleaned with a small, bottle brush or a damp cloth.
- How to Clean the OPTIONAL Heated Tube
Do not engulf the tube in water causing the Humidifier Connector End to become covered. Instead, hold the tube and gently rinse with warm water and mild soap. Make sure to clean each part of the hose including the connectors at the end of the cuff. The connectors should be cleaned, but they can not be immersed in water. Rinse thoroughly and allow the tube to dry completely before reconnecting the hose to the humidifier. Repeat this process weekly.
- How to Clean the Humidifier Base
Please Note: If the humidifier was recently used, the heater plate will remain hot for approximately 15 minutes following the end of therapy. To avoid potential burns, wait the allotted time to remove the water chamber.
Wipe the base and heater plate with a damp cloth. The base must be completely dry before being used.
DSXH
Specs
MoreN/A
N/A
Heated Tubing Flexible Plastic and Electrical Components
Mfg 2 Year
DSXH
Fast, free shipping on orders over $99
Get the best price with our 100% Price Protection Guarantee
Discounted replacements with Subscribe & Save
Try any CPAP mask for 30 days, risk-free
We recommend the following accessories
Respironics Pure White 6 Foot Performance CPAP/BiPAP 19mm Diameter Tubing with 22mm Ends
$8.25